IPSO Error Codes
If you are having trouble with an IPSO model machine displaying an error code, have a look at our list below to find out what the issue is.
Model: M20/M9
Fault Code | Fault |
"------------" |
BOARD RESETTING,CUTOUT ON SPIN ? CHECK DOOR HANDLE/LOCK
|
E4 |
WATER LEVEL NOT REACHED WITHIN 15MINS, WATER PRESSURE/DRAIN VAL
|
E5 |
TEMP NOT REACHED WITHIN 80 MINS
|
E6 |
DOOR UNLOCKED DURING WASH,FAULTY DOOR HANDLE/LOCK
|
E7 |
WATER DIDN’T DRAIN TO ALLOW SPIN, DRAIN VAL OR BLOCKAGE
|
E8 |
TEMPERATURE BELOW 5C OR ABOVE 95C FAULTY TEMPSENSOR TM140/204
|
EA |
TILT SWITCH ACTIVATED 15 TIMES, OUT OF BALANCE LOADING SHOCKERS DRAINAGE
|
Eb |
TILT SWITCH BLOCKED FAULTY
|
Model: M20
Fault Code | Fault |
E3 |
EPROM ERROR INCORRECT CHIP OR FAULTY BOARD
|
E9 |
MOTOR THERMAL PROTECTOR TRIGGERED
|
END |
DOOR FAILED TO OPEN,HANDLE/MECH OR SWITCHES
|
NOT2 |
SPEED ERROR CHECK WIRING IF PLUG IS FITTED/ SPEED SENSOR F7MAIN PULLEY LOOSE?TM215
|
NO DISPLAY |
CHECK DOOR LOCK HANDLE(DOOR LOCK MAYBE STUCK) THE DOOR MAYNOT OPEN !!!!!!!!!!!!!!!
|
Model: ALL
Fault Code | Fault |
CLOSE |
DOOR FAILED TO LOCK,HANDLE/MECH OR SWITCHES
|
Model: SIGMA
Fault Code | Fault |
OFF ECHO |
FAILED THERMAL CYCLE ,ENTER CODE AS FOLLOWS = PEPI SELECT(P) ECONOMY(E) SELECT (P) START ( I )
|
Model: PLC9
Fault Code | Fault |
1tE/2tE |
REQD TEMP WASN’T REACHED
|
3tE |
REQD TEMP WASN’T REACHED
|
cdo |
DOOR NOT CLOSED,INSPECT DOOR LOCK/HANDLE
|
4tE |
REQD TEMP WASN’T REACHED
|
E9 |
MOTOR TOC ACTIVATED
|
HLE at start |
AT THE START WATER LEVEL SWITCH FAULT HLE = HIGH LEVEL LLE LOW LEVELOR SLE-TILT
|
HLE during wash |
WATER LEVEL NOT REACHED (HLE HIGH LEVEL) ( LLE LOW LEVEL)
|
SLE at start |
LEVEL SWITCH MAY BE FAULTY/AIR DOME BLOCKED
|
SLE-tilt |
WATER LEVEL NOT REACHED
|
Model: PC30
Fault Code | Fault |
Error=04 |
FILLING TIME LONGER THAN 15MINS
|
Error=05 |
TEMP NOT REACHED WITHIN 60 MINS
|
Error=06 |
DOOR LOCK RELEASED DURING THE PROGRAM
|
Error=07 |
WATER IN THE TUB AFTER THE PROGRAM
|
Error=08 |
TEMP SENSOR FAILURE OR TEMP OUT OF RANGE
|
Error=09 |
THERMO-MAGNETIC PROTECTION WAS ACTIVATED
|
Error=10 |
TILT SWITCH WAS ACTIVATED
|
Error=11 |
WATER STILL IN DRUM AT START OF PROGRAM
|
Error=12 |
WATER STILL IN DRUM 3MINS AFTER DRAIN,HEATING NOT ACTIVATED
|
Error=13 |
REMOVE MOTOR WIRING IF INVERTER STILL ALARMS (INVERTER FAULTY)
|
Model: PS40
Fault Code | Fault |
A2 |
UNKNOWN PROGRAM SELECTED
|
A4 |
FILLING TIME LONGER THAN 15MINS
|
A5 |
TEMP NOT REACHED WITHIN 60 MINS
|
A6 |
DOOR LOCK RELEASED DURING THE PROGRAM
|
A7 |
WATER IN THE TUB AFTER THE PROGRAM
|
A8 |
TEMP SENSOR FAILURE OR TEMP OUT OF RANGE
|
A9 |
THERMO-MAGNETIC PROTECTION WAS ACTIVATED,NON INVERTER M/C'S ONLY
|
Ab |
WATER STILL IN DRUM AT START OF PROGRAM
|
Ac |
WATER NOT DRAINED WITHIN 3MIN'S,THERE WAS NO FURTHER HEATING
|
Ad |
NO RPM MEASURED DURING THE SPIN,INVERTER M/C'S ONLY
|
AH |
TILT'S PREVENTED SPIN
|
F5 |
THE DOOR WAS OPEN DURING THE PROGRAM
|
F6 |
THE DOOR WAS UNLOCKED DURING THE PROGRAM
|
FA |
TILT SWITCH BLOCKED
|
Model: 6000
Fault Code | Fault |
E9 |
MOTOR OVERLOAD CURRENT (DRAWN ABOVE 8AMP FOR 6000)
TRIAC ON MOTOR BOARD MUST BE BTB NOT BTA
|
NOT 3 |
5000 HRS ,CARBON BRUSHES REQD
|
NOT1/ "OOO" |
MOTOR OVERLOAD/MOTOR BOARD
|
NOT2 |
TACHO FAULT ON MOTOR,CHECK CIRCUIT
|
NOT2 /"OOO" |
SPEED ERROR,CHECK MOTOR BOARD/WIRING
|
Model: DIRONER
Fault Code | Fault |
HEAT |
TEMP BELOW 4oC OR ABOVE 190oC
|
NO AIR |
AIR FLOW SWITCH NOT O/C
|
NO HEAT |
HEAT NOT DETECTED 10SEC'S AFTER IT WAS ACTIVATED
|
NO SPEED |
SPEED DETECTOR NOT SENDING SIGNAL FOR SPEED
|