JLA Error Codes
Take a look at our handy lists of JLA fault codes below to determine what’s wrong with your machine.
Model: WASHER
Fault Code | Fault |
F10 |
TEMPERATURE NOT REACHED WITHIN MAX TIME FRONT BOARD/POWER
|
F11 |
NTS PROBE OR CIRCUIT FAILURE
|
F12 |
NTS SHORT CIRCUIT
|
F13 |
LEVEL SENSOR VOLTAGE LESS THAN .35VOLTS H-02
|
F14 |
P00 DOES NOT CORRESPOND WITH POWER BOARD,RESISTANCE R7 FAULT
|
F14/F20 |
CHECK FRONT BOARD BLOWN TRACKS AND POWER BOARD
|
F15 |
DOOR NOT CLOSED DURING OPERATION
|
F20 |
CONNECTION ON THE CHOPPER MODULE
|
F21 |
FREE-RUNNING DIODE SHORT CIRCUIT
|
F22 |
MAINS SURGE VOLTAGE
|
F23 |
IGBT SHORT CIRCUIT OR RELAY DEFECTIVE/CHECK MOTOR/CARBONS
|
F24 |
CHECK MOTOR/BOARD
MOTOR SPEED SENSOR DEFECTIVE
|
F25 |
TEMPERATURE DEFECTIVE
|
F26 |
MAINS FAILURE
|
H00 |
CHILD SAFETY DEVICE
|
H01 |
WATER LEVEL NOT REACHED WITHIN 6MIN
|
H02 |
WATER DIDN’T DRAIN.
|
H03 |
DOOR NOT CLOSED,INSPECT DOOR LOCK
|
H04 |
UNBALANCE TOO HIGH
|
Model: 6KG DRY
Fault Code | Fault |
F10 |
DRYING TOO SLOW
|
F11 |
FAILURE OF NTC PROBE OR CIRCUIT
|
F12 |
SHORT CIRCUIT IN THE PROBE CIRCUIT
|
F14 |
P00 DOES NOT CORRESPOND WITH POWER BOARD,RESISTANCE R7 FAULT
|
F15 |
NTC PROBE FOR OUT GOING AIR INTERRUPTED
|
F16 |
NTC PROBE FOR OUT GOING AIR SHORT CIRCUITED
|
F17 |
HEATING FAILURE CHECK ELEMENTS & CUTOUTS SEE TM226/ CHECK REAR BEARING
|
H00 |
CHILD SAFETY DEVICE
|
H01 |
NO FUNCTION ON THE MDB DRIER
|
H02 |
COOLING WATER OUTFLOW
|
H03 |
DOOR NOT CLOSED
|
H04 |
FLUFF FILTER IS BLOCKED
|