LUX Error Codes
Seeing an error code on your LUX machine? Take a look at our tables below covering several prevalent models to clarify what the problem is.
Model: EXACTA
Fault Code | Fault |
01E |
WATER LEVEL NOT REACHED WITHIN TIME
|
02E |
NO SIGNAL FROM THE DOOR CLOSED SWITCH
|
03E |
NO SIGNAL FROM THE DOOR LOCKED SWITCH
|
04E |
TEMP BELOW -5oC OR INTERRUPTION IN SENSOR
|
05E |
TEMP ABOVE 98oC OR SHORT CIRCUIT IN SENSOR
|
06E |
WATER TOO HI AT START OF PROGRAM ABOVE SAFE
|
07E |
WATER TOO HI DURING CYCLE
|
08E |
WATER TEMPERATURE RISES TOO SLOWLY
|
10E |
WATER LEVEL ABOVE SAFETY AFTER DRAIN SEQUENCE
|
11E |
MECHANICAL UNBALANCE ALWAYS ACTIVATED
|
12E |
CONTROL BOARD CANT READ EPROM
|
13E |
CONTROL BOARD CANT COMMUNICATE WITH MOTOR BOARD
|
14E |
WATER LEVEL NOT CALIBRATED
|
17E |
DOOR LOCKED DETECTED BUT DOOR NOT CLOSED
|
18E |
CALCAD 4400 DOSNT ALLOW START OF PROGRAM
|
19E |
COM BETWEEN CALCAD 4400 AND PROGRAM CARD INTERRUPTED
|
21E |
MICROPROCESSOR ERROR
|
22E |
LEVEL SYSTEM CANNOT AUTO CALIBRATE
|
31E |
MOTOR CONTROLLER HEAT SINK TEMP TOO HI
|
32E |
MOTOR THERMAL PROTECTOR TRIGGERED
|
33E |
MOTOR TOLD TO START BUT NO DOOR LOCKED SIGNAL
|
35E |
SHORT CIRCUIT IN MOTOR WINDINGS/CABLE OR CONTROLLER
|
36E |
MOTOR CONTROLLER INDICATES AN ERROR IN INTERLOCK RECEIVING CIRCUIT
|
37E |
THE MOTOR CONTROLLER INDICATES THE DC VOLTAGE
|
38E |
THE MOTOR CONTROLLER INDICATES THE DC VOLTAGE TOO HI
|
41E |
MOTOR CONTROLLER IND ERROR IN THERMAL PROTECTION CIRCUITS OF THE MOTOR
|
43E |
RDC CARD INDICATES IMBALANCE SWITCH TRIGGERED WHEN MOTOR IS STOPPED
|
45E |
RDC CARD INDICATES TACHO PULSES MISSING AT REQUESTED REV,S
|
Model: GEN2
Fault Code | Fault |
01 |
WATER LEVEL NOT REACHED SLOW FILL
|
02 |
DOOR LOCK DEFECTIVE
|
03 |
TEMP SENSOR DISCONNECTED FAULTY WIRING
|
04 |
TEMP ABOVE 98oC OR SHORT CIRCUIT IN SENSOR
|
05 |
WATER IN MACHINE BEFORE PROG START CHECK DRAIN, LEVEL SENSOR
|
06 |
MACHINE MEMORY FAULT CHIP FAULT
|
07 |
MACHINE HEATS INCORRECTLY CHECK HEATING SYSTEM
|
08 |
DRAIN TO LONG CHECK DRAIN VALVE, DRAINES, LEVEL SYSTEM
|
09 |
OUT OF BALANCE SWITCH INOPERATIVE
|
10 |
WITH WASH SPEED RELAY
SPIN RELAY ACTIVATED (DEFECT PCB-SPIN RELAY ACTIVATED TOGETHER
|
Model: GEN3
Fault Code | Fault |
0 1 |
WATER LEVEL NOT REACHED SLOW FILL
|
0 2 |
DOOR LOCK DEFECTIVE
|
0 3 |
TEMP SENSOR DISCONNECTED FAULTY WIRING???
|
0 4 |
TEMP SHORT CIRCUIT OR WATER TEMP OVER 98c
|
0 5 |
WATER IN MACHINE BEFORE PROG START CHECK DRAIN, LEVEL SENSOR
|
0 6 |
MACHINE MEMORY FAULT CHIP FAULT??
|
0 7 |
MACHINE HEATS INCORRECTLY CHECK HEATING SYSTEM
|
0 8 |
DRAIN TO LONG CHECK DRAIN VALVE, DRAINES, LEVEL SYSTEM
|
0 9 |
OUT OF BALANCE SWITCH INOPERATIVE
|
18 |
WASH PROG NOT PAID MUCH WILL NOT START BEFORE PROG FULLY PAID FOR
|
19 |
COMMUNICATION FAILED COMMUNICTION FROM PCB TO PAYMENT SYSTEM
|
Model: GEN 5
Fault Code | Fault |
01E |
WATER LEVEL NOT REACHED SLOW FILL
|
02E |
DOOR STATUS ACKNOWLEDGEMENT SIGNAL NOT RECEIVED
|
03E |
DOOR LOCK ACKNOWLEDGEMENT SIGNAL NOT RECEIVED WITHIN TIME
|
04E |
TEMP SENSOR DEVICE INDICATES TEMP BELOW -5C
|
05E |
TEMP SENSOR DEVICE INDICATES TEMP ABOVE 98C
|
06E |
WATER IN MACHINE BEFORE PROG START CHECK DRAIN, LEVEL SENSOR
|
07E |
WATER LEVEL SIGNAL ABOVE PARAMETER SET FOR SAFETY DURING PROG
|
08E |
INCREASE IN WATER TEMP IS BELOW PARAMETER SET
|
10E |
SLOW DRAIN / PRESSURE SYSTEM FAULT
|
12E |
THE PROG CONTROL UNIT CANNOT READ THE PROG EPROM
|
13E |
THE PROG CONTROL UNIT RECEIVES NO RESPONSE FROM THE MOTOR
|
14E |
WATER SYSTEM NOT CALIBRATED
|
15E |
DOOR LOCK FAULT THE LOCK HAS A MECHANICAL FAULT
|
16E |
WRONG CALIBRATED WEIGHT MEASURING SYSTEM. PRESS START
THE PROGRAM WILL NOW RUN/BUT THE WEIGHT WILL BE SET TO 5KG.
|
17E |
DOOR LOCKED DETECTED BUT DOOR NOT CLOSED
|
18E |
ONLY WITH CALCAD 4400. FULL PAYMENT HAS NOT BEEN RECEIVED FOR
THE PROGRAM. OR THE BOOKING TIME IS TOO SHORT FOR PRO TO FINISH
|
19E |
COMM'S BETWEEN CALCAD 4400 AND THE PROG/CONTROL UNIT INTERUPTED.
|
20E |
MOTOR CONTROL UNIT HAS NOT RECEIVED SIGNAL FOR LOCK DURING PROG.
|
31E |
TEMP OF MOTOR CONTROL UNIT. HEAT SINK TOO HIGH.
|
32E |
THERMAL PROTECTION FOR MOTOR HAS CUT OUT.
|
33E |
THE MOTOR CONTROL UNIT HAS RECEIVED A START COMMAND FROM THE
PROG CONTROL UNIT, WITHOUT HAVING THE INTERLOCK SIGNAL. NO FAULT
|
35E |
MOTOR CONTROL UNIT INDICATING SHORT CIRCUIT BETWEEN MOTOR
|
Model: SELECTA
Fault Code | Fault |
E 01 |
INLET AIR-INPUT -INTO THE DRUM IS TO HIGH
|
E 02 |
OUTLET AIR- OUTPUT TEMP FROM THE DRUM IS TO HIGH
|
E 03 |
INLET AIR-SENSOR SHORT-CIRCUIT THERMISTOR ELEMENT/ WIRING FAULT
|
E 04 |
OUTLET-SENSOR HAS SHORT-CIRCUITED THERMISTOR/WIRING FAULT
|
E 05 |
BLOWER MOTOR 1 THERMAL PROTECTION OR WIRING TO MOTOR O/C
|
E 06 |
DRUM MOTOR 2 THERMAL PROTECTION OR WIRING TO MOTOR O/C
|
E 07 |
OPTION NOT USED
|
E 08 |
INLET & OUTLET AIR PROTECTION THERMOSTATS ONE OF THE PROTECTION
THERMOSTATS HAVE TRIPPED O/C DUE TO OVERHEATING
|
E 09 |
LINT DRAWER-LINT DRAWER MUST BE CLEANED BEFORE START OF MCH
|
E 10 |
SETTING-PROGRAMMING ERROR/I INCORRECT OR MISSING PARAMETERS
|
E 11 |
(NONE COIN)
DRYING ERROR-MAX RMC TIME EXCEEDED
|
E 12 |
DRYING ERROR-MAX AUTOSTOP TIME EXCEEDED
(NONE COIN)
|
E 13 |
DRYING ERROR- REQUSTED DRYING TIME IS LONGER THAN MAX ALLOWED
(DRYER CONNECTED TO A PAYMENT SYSTEM)
|
E 14 |
GAS ERROR- A FLAME WAS NOT DETECTED ON GAS HEATED DRYERS
|
E 15 |
VACUUM SWITCH-(SAIL SWITCH)THE VACUUM SWITCH DOES NOT SHUT
|
E 16 |
VACUUM SWITCH-(SAIL SWITCH) THE VACUUM SWITCH WAS CLOSED
WHEN AN ATTEMPT TO START THE DRYER
|
E 17 |
INPUT SENSOR-DISCONNECTED INLET THERMISTOR/WIRING IS O/C
|
E 18 |
OUTPUT SENSOR-DISCONNECTED OUTLET THERMISTOR/WIRING IS O/C
|
E 20 |
CMIS IS NOT MONITORING THE MACHINE. THE MACHINE IS DEACTIVATED
IN THE CMIS PROG.
|
E21 |
COMM'S BREAK DOWN CMIS. THE COMM'S HAS STOPPED. MCH WILL START,
|
E22 |
COMM'S BREAK DOWN LM10. THE COMM'S HAS STOPPED. MCH WILL NOT START.
|
E99 |
COMM'S ERROR. THE USER MODULE DOES NOT RECEIVE COMM'S FROM THE MAIN BOARD.
|