Miele Error Codes
Our tables below can help you figure out exactly what an error code on your Miele machine means.
Model: 5425/26
Fault Code | Fault |
PRE-WASH |
LED (0.1ON 0.1OFF) LEVEL SWITCH FAULT
|
MAIN WASH |
LED (0.1ON 0.1OFF) NTC FAULT
LED (0.1ON 0.1OFF) CORRECT TEMP NOT REACHED DURING THERMOSTOP
|
RINSE |
LED (0.1ON 0.1OFF) TACHOGENERATOR FAULT CHECK MOTOR CARBONS/WIRING
|
TAP/RED |
LED (0.1ON 0.1OFF) SLOW FILL CHECK FILTERS/ UP FILL TIME SEE PROG MODE1 (5/9)
|
DRAIN/RED |
LED (0.1ON 0.1OFF) SLOW DRAIN CHECK PUMP/D VALVE DRAIN BLOCKAGE
|
LED ON/START |
LED (0.5ON 0.5OFF) SELECTED PROG CHANGED DURING PROG LED WILL STOP FLASHING WHEN PROG AT THE START IS RESECLECTED, WHICH NORMALLY IS ( SLUICE PROG )SELECT IN ERROR (CHECKPROG SWITCH CAM MAYBE FAULTY) A SLUICE PROG CAN ONLY BE ENDED DURING THE WASH BY ADDING A FAULT OR RESET POWER BOARD PLUG 2 WIRE WITH LINK (IF FITTED)
|
LED PRE-WASH |
LED (0.5 ON 0.5OFF) - SERVICE MODE
|
PRE +MAIN WASH |
LED (0.5 ON 0.5OFF) - PROGRAMMING MODE 1 / 2
|
MAIN WASH |
LED (0.5 ON 0.5OFF) - PROGRAMMING MODE 3
|
LED STARCH |
LED (0.5 ON 0.5OFF) - REMINDER TO ADD STARCH
|
LED DRAIN |
LED (0.5 ON 0.5OFF) - RINSE HOLD
|
LED PROG SEQ |
LED (0.5 ON 0.5OFF) TIME EXPIRED WITH COIN MECHANISM
|
Model: PW
Fault Code | Fault |
F0 |
* NO FAULTS LISTED IN HISTORY
|
F1 |
* NTC FAULT CHECK RESISTANCE , & OPEN OR SHORT CIRCUIT THE
|
F2 |
* CHECK AS ABOVE F1
|
F10 |
DISPLAY= WATER INLET FAULT SLOW FILL ,TIME CAN BE EXTENEDED VIA
|
F11 |
DISPLAY=WATER DRAINAGE FAULT CHECK DRAIN PUMP/ VALVE/ DRAINES
|
F15 |
* HOT INLET FAULT PROGRAMME CONTINUES WITH COLD WATER
|
F16 |
DISPLAY=AT THE END OF THE PROGRAMME =EXCESS FOAM (OVER SOAP)
|
F20 |
* HEATING THE CORRECT TEMPERATURE HAS NOT BEEN REACHED
|
F41 |
EEPROM/ DATA FAULT DISPLAY= TECHNICAL FAULT PROGRAMME IS INTERRUPTED(REPLACE POWER-PROGRAMME MODULE (ELP)
|
F43 |
MODEL TYPE NOT PROGRAMMED DISPLAY= TECHNICAL FAULT THE SELECTION MODULE (EW) AND THE POWER-PROGRAMME MODULE (ELP) DO NOT MATCH CHECK MAT. NOS.TO VERIFY CORRECT SELECTION
|
F44 |
DISPLAY=TECHNICAL FAULT I 2 C BUS CONNECTION FAULTY PROGRAMME IS INTERRUPTED REPLACED (ELP) MODULE
|
F45 |
FAULTY FLASH RAM/INCORRECT DATA CHECK MAT.NOS.TO VERIFY THAT THE CORRECT SELECTION MODULE(EW) AND POWER-PROGRAMMED MODULE (EPL,) ARE FITTED USE THE RESET PROGRAMME FUNCTION TO TO RESET ALL STANDARD SETTINGS THEN REPROGRAMME/ REPLACED(ELP)
|
F46 |
DISPLAY FAULT (EW) LCD DRIVER DEFECTIVE REPLACE (EW)
|
F47 |
(EW)-POWER-PROGRAMME MODULE (ELP) INTERFACE FAULT CHECK CONNECTIONS BETWEEN (EW) AND THE (ELP) MODULE
|
F50 |
DISPLAY=TECHNICAL FAULT DRIVE FAULT MOTOR/INVERTER FAULT
|
F51 |
DISPLAY=TECHNICAL FAULT ANALOG PRESSURE SENSOR(ADS) FAULT PRESSURE SENSOR INTEGRATED IN THE (ELP) MODULE
|
F53 |
DISPLAY=TECHNICAL FAULT TACHOGENERATOR DEFECTIVE/WIRING
|
F56 |
NO SPIN ,SPIN SPEED<400 RPM SELECTED SPIN ABOVE 450 RPM SEE F16
|
F63 |
DISPLAY=TECHNICAL FAULT WATER PATH CONTROL FAULTY(FILL FAULT ?)
|
F65 |
DRUM LIGHTING CAP MISSING DISPLAY =DRUM LIGHTING
|
Model: PT
Fault Code | Fault |
F0 |
NO FAULTS
|
F1 |
HEATER BANK NTC SHORT CIRCUIT
|
F2 |
HEATER BANK NTC OPEN CIRCUIT
|
F3 |
FILL RING NTC SENSOR SHORT CIRCUIT
|
F4 |
FILL RING NTC SENSOR OPEN CIRCUIT
|
F41 |
FAULTY EEPROM/DATA FAULT
|
F43 |
MODEL TYPE NOT PROGRAMMED
|
F45 |
FAULTY FLASH RAM/DATA FAULT
|
F46 |
DISPLAY FAULT
|
F47 |
COMM'S FAULT BETWEEN EW/ELP ELECTRONIC MODULES
|
F50 |
MOTOR STATIONARY & HEATING OPERATES FOR 5,SEC
|
F55 |
OVERRIDING TIME LIMIT EXCEEDED
|
F66 |
AIR LEAKAGE FAULT
|
Need assistance with your Miele machine? Call us now on [ld_default] to book an engineer. We’re always here to help