Grandimpianti Error Codes
If your Grandimpianti machine starts showing an error code, our useful list of common codes can help you establish the problem.
Model: WR-EC
Fault Code | Fault |
E1 |
WATER IN DRUM BEFORE START OF PROG FUNCTIONS DISABLED UNTIL LEVEL IS BELOW SAFETY LEVEL
|
E2 |
WATER LEVEL ALARM, REQUIRED LEVEL WAS NOT REACHED WITHIN 5 MINS (ALARM WILL STOP WHEN THE REQUIRED LEVEL HAS BEEN REACHED)
|
E3 |
DRAIN ALARM WATER HAS FAILED TO DRAIN BELOW SAFETY LEVEL AFTER 1 MINUTE CYCLE WILL RESUMED ONCE LEVEL IS BELOW SAFETY LEVEL
|
E4 |
HEATING ALARM TEMP HAS NOT RISEN BY AT LEAST 5C IN 20MINS, ALARM WILL STOP WHEN CORRECT TEMP IS ESTABLISHED
|
E5 |
OVERTEMPERATURE ALARM, DISCONNECTED TEMP PROBE WATER TEMP HAS EXCEEDED 95oC CYCLE ABORTED
|
E6 |
DOOR LOCK ALARM 10 SEC,S AFTER CYCLE START DOOR HAS FAILED TO LOCK, WASH CYCLE IS ABORTED
|
E7 |
DOOR ALARM ,DOOR DAMAGED DURING CYCLE, CYCLE ABORTED
|
E8 |
LEVEL ALARM WATER LEVEL 10CM ABOVE SET LEVEL CYCLE ABORTED
|
E9 |
WATER IN DRUM AFTER SPINNING MOTOR WILL BE DISENERGISED FOR 90 SEC,S THEN A DISTRIBUTION STEP FOR 90 SEC,S TO REMOVE WATER E9 WILL BLINK DURING,THE ABOVE WILL BE ATTEMPTED UPTO 15 TIMES
|
E0 |
MOTOR OVERLOAD CUT OUT THE CYCLE WILL BE ABORTED
|
1000C |
TO RESET PRESS (-) KEY FOR 5 SEC,S WITH THE DOOR CLOSED,CYCLES ARE DISPLAYED, WITHIN 10 SEC,S PRESS (-) KEY TO RESET (REMOVE OFF PCB IF KEYPAD IS NONE RESPONSIVE)
|
Need assistance with your Grandimpianti machine? Call us now on [ld_default] to book an engineer. We’re always here to help