FR-E500 Error Codes
At a glance, an error code on your FR-E500 machine is inscrutable – check out our table below to find out what common codes actually mean.
Model: INVERTER
Fault Code | Fault |
E.r Hn |
MOTOR OVER CURRENT OVER HEAT
|
E.r Hr |
MOTOR CURRENT MORE THAN 150 PERCENT OF RATED OUTPUT CHECK INVERTER PARAMETERS, COMMON FAULT CODE PARTIAL BLOCKAGE OF DRAIN !! COMMON FAULT
|
E.FI n |
INVERTER OVER HEAT (HEAT SINK) CHECK LINT BUILD UP AND COOLING FAN
|
E. bE |
BREAK TRANSISTOR ALARM (ONLY WHEN FITTED WITH BREAK RESISTOR)
|
E. CF |
EARTH FAULT ON LOAD SIDE (MOTOR)
|
E. 0Hr |
OPEN CIRCUIT ON MOTOR THERMALS OR THERMAL RELAY
|
E. 0Lr |
RUNNING FREQUENCY HAS FALLEN TO ZERO. STALL PREVENTION ACTIVATED CHECK MOTOR OVERLOAD. REDUCE LOAD WEIGHT.
|
E.0Pr |
STOPS THE INVERTER OUTPUT. FUNCTION FAULT. COMMUNICATION ERROR. CHECK CABLES.
|
E. PE |
PARAMETER STORAGE DEVICE ALARM. FAULT OCCURRED IN PARAMETERS
|
E. PUE |
PARAMETER UNIT DISCONNECTION
|
E.r Er |
RETRY COUNT EXCEEDED. FIND CAUSE OF ALARM OCCURENCE.
|
E.CPU |
CPU ERROR. BUILT IN CPU DOES NOT END IN A PREDETERMINED PERIOD.
|
E. 3 |
OPTION FAULT. CHECK PARAMETERS. COMMUNICATION PROBLEM.
|
E. 6 |
CPU ERROR IN BUILT IN CPU. COMMUNICATION ERROR
|
E. 7 |
CPU ERROR IN BUILT IN CPU. COMMUNICATION ERROR
|
E.LF |
OUTPUT PHASE PROTECTION. OPEN CIRCUIT ON PHASE U.V.W LOAD SIDE
|
F n |
FAN FAULT. INVERTER COOLING FAN FAULT. ALSO CHECK PARAMETER P244
|
0L |
STALL PREVENTION OVERCURRENT (IF A CURRENT OF MORE THAN 150% FLOWS). CHECK PARAMATER PR22. DEFAULT = 150%. TURN OFF OPTION PR156
|
O L |
STALL PREVENTION OVER VOLTAGE. EXCEEDED BRAKE CAPABILITIES. MOTOR (CHECK INVERTER BOOKLET FOR A MORE COMEREHENSIVE LIST)
|
Need assistance with your Mitsubishi machine? Call us now on [ld_default] to book an engineer. We’re always here to help